High temperatures

TEMPERATURE CYCLING TEST UNIT

Secure Connections at High Temperatures

The temperature cycling testing device evaluates the durability of connections in piping systems with rigid or flexible thermoplastic pipes under temperature fluctuations. This is especially relevant for piping systems designed for pressurized water applications with hot and cold water. Using a pressure vessel, temperatures of up to 114 °C can be achieved, allowing you to perform your tests under realistic operating conditions and ensuring the safety and reliability of your connections.

Standards

Keine Standards gefunden

  • ISO 10508
  • DVGW W 542
  • DVGW W 543
  • DVGW W 534

Features and Functionality

Automatically running tests with programmable cycle counts, durations, temperatures, etc.
Allows simultaneous testing of multiple piping systems
Tensioning apparatus equipped with a load cell and instrumentation for measuring initial tensile stress
Option to adjust the flow rate in the individual test line (optionally also controlled)
User-friendly operation and clear visualization via PC control
Microprocessor-driven, adaptive pressure control with automatic break detection
Specimen frame arranged diagonally to allow better accessibility
Maintains constant test temperature with large storage capacity. Ensures high pressure accuracy and precise flow regulation
Interface to IPT DataLogging®
Measurement and recording of flow rates
High-quality equipment components ensure excellent machine availability, long service life, and low maintenance costs
With the help of a pressure vessel, temperatures of up to 114 °C can be achieved

The product family

  • Tests on finished products
  • Additional testing equipment
The temperature cycling test device evaluates the resistance of joints in thermoplastic piping systems with rigid or flexible pipes to temperature change stresses. It is designed for systems used in pressurized hot and cold water applications.

Standards

  • ISO 10508
  • EN 12293
  • DVGW W 542
  • DVGW W 543
  • DVGW W 534
  • Tests on finished products
  • Additional testing equipment

The temperature change tester allows you to determine the resistance of connections for pipe systems with rigid or flexible thermoplastic pipes to temperature changing stress.

Standards

  • DVGW W 534
  • DVGW W 543
  • DVGW W 542
  • ISO 19892
  • EN 12293
  • Tests on finished products
  • Additional testing equipment

This test determines the resistance of pipe system connections to thermal cycling

Standards

  • EN 1055