Creep and burst tests

AIRLESS ADVANCED

Professionally pressure tested

The purpose of this tester is to apply and maintain the correct hydrostatic pressure for internal pressure creep tests. Bursting pressure tests can also be optionally performed. The internal pressure creep test is a test procedure for determining the strength of thermoplastic pipes when exposed to constant internal water pressure at a constant temperature. The samples are subjected to a defined and constant hydrostatic internal pressure for a specified period or until they fail. The load on the specimen is defined by the stress (by means of internal pressure) and the temperature. The testing device (base unit) has a modular design and can be equipped with up to 45 test stations. The test device is supplied with the required high-pressure water via the integrated pressurised water supply or a pressurised water supply from existing racks (base or expansion units).

Standards

Keine Standards gefunden

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599

Downloads

Features and Functionality

A maximum of nine airless modules can be installed in the 1814 installation frame. A maximum of 45 test stations for time-dependent pressure tests or 12 test stations for burst pressure tests can be installed.
Up to four extension cabinets (without their own pressurised water supply) can be connected to the installation frame. The configuration varies depending on requirements, with a maximum of up to 60 test stations per extension rack for internal pressure tests or a maximum of 16 test stations for burst pressure tests.
In addition to the modules, the rack contains the pressurised water supply for generating the pre-pressure, the power supply and a status display.

Pressurised water supply

The pipe tester is supplied with the required high-pressure water via the integrated pressurised water supply (6, 12 or 24 litres/min.) or a pressurised water supply from existing frames (base or expansion units). The pressurised water supply consists of:
  • Water inlet with water filter and pre-pressure monitoring
  • Pressure vessel (buffer tank): Prevents pressure peaks and temporarily increases the water supply capacity.
  • Controller: For controlling the high-pressure pump and monitoring the system pressure.

Module and controller

For each module, a controller (microprocessor control) individually controls and regulates the pressure of the individual stations. For pressure control, each station has two solenoid valves and a pressure transducer. The solenoid valve MV1 regulates the pressure build-up. The solenoid valve MV2 is used for pressure reduction and pressure relief at the end of the test.

Options

Precision pressure measurement instrument 1817 (master gauge): An external precision pressure measurement instrument can be connected via a needle valve bar in order to check the test pressure before or during a test. The test pressures of the individual stations can be easily checked with the master gauge. They can then be readjusted if necessary if a pressure measurement accuracy of 0.3% of the final value of the pressure transducer does not appear to be sufficient.

Periphery and Complementary

  • Tests on finished products
The creep internal pressure test is a test method for determining the strength of thermoplastic pipes.

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Tests on finished products

The internal pressure creep test is a test procedure for determining the strength of thermoplastic pipes.

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Tests on finished products

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Tests on finished products

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Tests on finished products
For burst pressure tests up to 200 bar on plastic fittings with inside diameter up to 160 mm with 3-dimensional loading. 

Standards

  • ASTM D 1599
  • Sample preparation
To produce test specimens for creep pressure tests, falling weight tests, heat reversion tests, or tests with the methylene chloride tester, the pipe lengths must be cut to standard dimensions. 
  • Tests on finished products
The end clolsures model 1810 are designed for the quick sealing of plastic pipes up to DN 2700 mm and are characterised by easy handling – simple, brilliant and inexpensive.

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Tests on finished products
The internal pressure creep test is a test procedure for determining the strength of thermoplastic pipes to constant hydrostatic internal pressure at a constant ambient temperature.

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Tests on finished products

The internal pressure creep test is a test procedure for determining the strength of thermoplastic pipes when exposed to constant hydrostatic internal pressure at

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Software

The product family

For peak performance

  • Tests on finished products
  • Tests on raw materials
The purpose of this tester is to apply and maintain the correct hydrostatic pressure for internal pressure creep tests. Bursting pressure tests can also be optionally performed.

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599

Precise and consistent

  • Tests on finished products

For mid-level testing demands, the Airless Blue Line ensures pressure control at maximum adjustment precision and consistency.

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599

Flexible

  • Tests on finished products
The 1790 Airless Light Line full set, with its five pressure stations and test bath, provide a simple all-in-one solution. The operation, evaluation of the results and clear visualization is done via a laptop.

Standards

  • ISO 1167
  • ASTM D 1598

To get started

  • Tests on finished products

The 1799 full set combines five pressure stations and a test bath in a single housing.

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599
  • Tests on finished products

Standards

  • ISO 1167
  • ASTM D 1598
  • ASTM D 1599